Abstract:The traditional pumping test is mainly a single-well pumping test. It is not accurate to obtain the relevant hydrogeological parameters, and there are large errors. Taking a deep foundation pit project in Shanghai as an example, the maximum excavation depth of the foundation pit is 25.8 m. And the two layers of ⑦1 silty sand with silty clay and ⑦2 silty sand are interconnected. The group-well pumping test for ⑦ layer soil is carried out. The tested data are fitted and analyzed. The average value of the water conductivity coefficient is T=115 m2/D, the average value of the horizontal permeability coefficient is Kh=4.61 m/d and kv=0.155×4.61 m/d=0.71 m/d, and the water storage coefficient is S=1.31×10-3 , which provide the important reference for dewatering construction of foundation pit engineering.