Abstract:For the leakage problem of underground station in water-rich soft soil layer in Shanghai and based on the analysis of concrete cracking principle, the finite element damage model of concrete structure of subway station is established. It reveals the characteristics of concrete crack initiation, the distribution and development law of concrete cracks under load of soil and water. In this paper, the temperature-strain field experiment of concrete is carried out by using fiber grating monitoring technology, and the temperature of concrete structure and law of its strain variation in the whole process of construction is obtained. Impact analysis of the temperature, maintenance time, anti-crack agent and other factors is made on the issue of the concrete cracking. The research shows that there are through and non-through cracks according to their morphological characteristics, in which the through cracks can cause the leakage of the station structure. Because of the constraints, the through-crack mainly occurs in the sidewall near the middle plate and soleplate. Adding anti-crack agent and prolonging maintenance time can effectively improve concrete crack resistance and waterproof impermeability.