Abstract:Taking a special-shaped steel-pylon steel-girder cable-stayed bridge as an example, the structural force of the system bridge is analyzed and evaluated. In view of the unique modeling of the bridge pylon, the structural calculation software is used to analyze its overall force. The analysis result verifies the design safety and construction rationality of the bridge structure. At the same, some reasonable suggestions are put forward for the design of the similar bridges.