Abstract:By the comparison of retaining design schemes for high-voltage tower on a high cutting slope of Tuoxi Expressway in Jianzhou Harbor Economic Zone of Jianyang, the prestressed anchor cable single-row pile support method is recommended to retain the slope. And this support scheme is verified by a finite element method. The results shows that the stability acceptance safety factor of the adopted support scheme is 2.313, and the control index inclination of high-voltage tower structure is 0.105%, which can all meet the specification requirements. This support scheme can ensure the operational safety of the road and the high-voltage tower. The prestressed anchor cable anti-slide pile support to be used can effectively control the ground settlement of the slope top in the similar high cutting slope sections.