Abstract:The joint box of underground diaphragm wall is widely used in the construction of underground diaphragm wall. Accidents occur when the joint box is buried on occasion. Based on the engineering practice of the actual projects, the causes of the buried joint box are comprehensively analyzed. Two causes including the technology and construction environment are summarized. Several disposal measures for the buried joint box are proposed respectively three kinds of crane topping pulling, oil topping with crane topping pulling and lateral stripping. Based on the accident of the buried joint box in a waterworks extension project, the cause analysis, practical disposal measures and disposal results of the accident are given. Finally, some construction suggestions are put forward in order to provide the effective solutions for the relative accidents.