Abstract:Aiming at the demand for flood control and waterlogging prevention in a block of Shengzhou City, a design scheme of rainwater pumping station system based on the 50 a flood control standard is proposed. The principle of "zoned governance and separation of rainwater and sewage" is adopted in the project. Two pumping stations with the design flows of 16.3 m3/s and 11.5 m3/s are constructed, respectively, which are supported with 10 000 m3 and 7 770 m3 initial rainwater storage tanks. By building an "initial rainwater storage + staged discharge" operational mode, combined with the “ion oxidation-activated carbon adsorption” stepped deodorization system, the dual objectives of flood control and waterlogging drainage and environmental protection are realized. After the project completion, the flood control capability of the area will be obviously enhanced. At the same time, the pollution of initial rainwater is effectively controlled, which provides the referenceable technical schemes for the construction of flooding control engineering in the similar new urban areas.