Abstract:To investigate the reflected-wave response and defect identification capability of the low-strain method in pile foundation integrity testing and based on one-dimensional wave theory and the pile-soil dynamic interaction mechanism, a two-dimensional axisymmetric numerical model is established to simulate and analyze the intact piles and piles with different defects. The results show that the reflected wave of an intact pile is mainly characterized by the pile-end echo, whereas necking and pile breakage defects produce clear early reflections. The amplitude of the reflection peak increases markedly with the increase in the cross-sectional reduction ratio. The defect reflection time exhibits a good linear relationship with the defect depth, and the deviation between the numerical results and theoretical values is less than 0.20 ms, indicating that the low-strain method has good reliability in defect location. A wave velocity disturbance of ±10% can cause a depth inversion error of approximately ±0.30m, while increasing the impact energy can improve the stability of the reflected signal. The findings provide a reference for parameter optimization in low-strain testing and quantitative identification of pile defects.