Abstract:In view of the fact that there is no dedicated independent specification for the structural design of anaerobic reactors and the applicability problem of long-term reference to cross-industry standards such as Design Specification for Vertical Cylindrical Steel Welded Oil Tanks (GB 50341-2014), a comparative analysis of the structural responses of multi-sized anaerobic reactors is carried out. Through the establishment of multi-scale finite element models, the standard formulas and numerical analysis methods are used for parallel calculation and comparative research to quantitatively reveal the difference patterns between the standard design and the numerical simulation results. A two-stage design method balancing safety and cost-effectiveness is accordingly proposed. The tank wall thickness is preliminarily determined on the basis of current specifications, and then a refined finite element model is established to conduct multi-condition stress analysis and evaluation under actual process loads so as to verify and optimize the initial design scheme, which can provide references for the safe and economical design of similar anaerobic reactors.