Abstract:Stay cables are the critical load-bearing components of cable-stayed bridges, and their cable force directly affects the safety and durability of the whole bridge structure. Taking stay cable C01-001-01 of a cable-stayed bridge as the research object, and based on field measured vibration data, the spectral analysis method is used to identify and evaluate the stay cable force. During the monitoring, the high-sensitivity accelerometers are adopted to continuously collect the vibration signals of stay cable at a sampling frequency of 50 Hz for a total monitoring duration of 625.95 s, yielding 31 298 valid data points. Time-domain statistical analysis on raw vibration signals gives a mean amplitude of 0.000 112, standard deviation of 0.001 294, peak-to-peak value of 0.012 and crest factor of 4.62, which indicates the cable vibrates slightly under ambient excitation. Fast Fourier Transform (FFT) and Power Spectral Density (PSD) are used to extract the fundamental frequency of the cable at 1.596 Hz, and the cable force is calculated according to the string vibration theory formula. The results reveal that the measured cable force is within the allowable design range, and the cable works normally. The effectiveness of the vibration method in monitoring the cable force of cable-stayed bridges is verified, providing a reference for the health monitoring of similar bridges.