    摘要:

    针对高降雨地区高速公路路基受降雨入渗及毛细水迁移影响导致含水率升高的问题,依托云南瑞丽至弄岛高速公路试验段,采用超疏水聚合物构建路基隔水层,并基于FDR技术开展连续原位含水率监测。试验段全长100 m,其中超疏水试验段与普通路基对照段各50 m,共布设5组FDR传感器。结果表明:30~60 cm浅层含水率波动最明显,主要为12%~18%;80 cm附近波动明显减弱;100~140 cm深层含水率较高,多维持在24%~34%。与对照区相比,试验区浅层含水率峰值及波动幅值明显减小,响应存在一定滞后,且深层高含水率未持续向0~80 cm隔水包裹区传递,表明超疏水隔水层可有效削弱路基内部水分迁移,提高水分场稳定性。

    Abstract:

    To address the increase in moisture content of highway subgrades in high-rainfall regions caused by rainfall infiltration and capillary water migration, a field test section of the Ruili–Nongdao Expressway in Yunnan Province was selected. A superhydrophobic polymer was used to construct a water-barrier layer in the subgrade, and continuous in-situ moisture-content monitoring was conducted using frequency domain reflectometry (FDR). The test section was 100 m long, consisting of a 50 m superhydrophobic treatment section and a 50 m conventional subgrade control section, with five groups of FDR sensors installed. The results showed that moisture fluctuations were most pronounced in the shallow layer at depths of 30–60 cm, where the volumetric water content mainly ranged from 12% to 18%; the fluctuations decreased markedly near a depth of 80 cm; and the deeper layer at depths of 100–140 cm maintained relatively high moisture contents, generally ranging from 24% to 34%. Compared with the control section, the superhydrophobic treatment section exhibited significantly lower peak moisture contents and smaller fluctuation amplitudes in the shallow layer, together with a certain lag in moisture response. Moreover, the high moisture content in the deeper layer did not continuously propagate into the 0–80 cm zone enclosed by the water-barrier layer. These results indicate that the superhydrophobic water-barrier layer can effectively suppress moisture migration within the subgrade and improve the stability of the internal moisture field.

    参考文献
    相似文献
    引证文献
引用本文

王治波.高速路基超疏水隔水层施工与隔水效果监测[J].城市道桥与防洪,2026,(11):338-343.